760 research outputs found

    Experimental evaluation of shear and compression strength of masonry wall before and after reinforcement: Deep repointing

    Get PDF
    Masonry presents some inadequacies due to its almost total lack of tensile strength. Typical damage to multiple leaf walls during earthquakes is the loss of bond between the leaves with consequent collapse of the external leaf. Retrofitting or repair of this damage is a very difficult task. In many cases grout injection or wall jacketing fail due to incompatibility with the construction technique of the walls. A complementary technique to the grouting has been proposed by the authors. Experimental results and applications of the technique on site have shown positive characteristics and the results of tests carried out on site show, in some cases, increases in shear strength and stiffness of the masonry walls

    Calibration of a visual method for the analysis of the mechanical properties of historic masonry

    Get PDF
    The conservation and preservation of historic buildings affords many challenges to those who aim to retain our building heritage. In this area, the knowledge of the mechanical characteristics of the masonry material is fundamental. However, mechanical destructive testing is always expensive and time-consuming, especially when applied to masonry historic structures. In order to overcome such kind of problems, the authors of this article, proposed in 2014 a visual method for the estimation of some critical mechanical parameters of the masonry material. Based on the fact that the mechanical behavior of masonry material depends on many factors, such as compressive or shear strength of components (mortar and masonry units), unit shape, volumetric ratio between components and stone arrangement, that is the result of applying a series of construction solutions which form the "rule of art". Taking into account the complexity of the problem due to the great number of variables, and being on-site testing a not-always viable solution, a visual estimate of the mechanical parameters of the walls can be made on the basis of a qualitative criteria evaluation. A revision of this visual method is proposed in this paper. The draft version of new Italian Building Code have been used to re-calibrate this visual method and more tests results have been also considered for a better estimation of the mechanical properties of masonry

    Masonry wall panels retrofitted with thermal-insulating GFRP-reinforced jacketing

    Get PDF
    Today there is a need to provide thermally efficient walls, while at the same time to increase the mechanical properties of old unreinforced masonry walls that will not require large amounts of energy in the retrofitting or deconstruction processes. To address this problem, this paper gives the results of shear tests carried out on masonry panels made of solid bricks retrofitted with a new technique based on the use of glass fiber-reinforced polymers (GFRP) grids inserted into a thermal insulating jacketing. This was made of different low-strength lime-based mortars. Tests were carried out in laboratory and results were used for the determination of the shear modulus and strength of the wall panels before and after the application of the GFRP reinforcement. Retrofitted panels exhibited a significant enhancement in the lateral capacity when compared to the control panels. The thermal performance of the proposed mortars was also investigated both with and without GFRP. Low values of thermal conductivity were found, especially for the samples with GFRP; a reduction of the thermal transmittance value in the 34–45 % range was also obtained by applying 45 mm layer of coating in conventional masonry walls

    Sustainable Strengthening Techniques for Masonry Structures

    Get PDF
    Reducing the energy consumption is an important objective of the construction industry and this also applies for renovation, retrofit and refurbishment of existing buildings. Masonry buildings often need to be retrofitted and the use of Fibre Reinforced Polymeric (FRP) materials has proven to be a viable solution. With the inevitable declining of fossil fuels, carbon fibres and epoxy resins must be substituted with greener materials. This paper reports the results of several experimental investigations recently conducted by the authors using glass fibre meshes embedded into an inorganic matrix (known as FRCM: Fibre Reinforced Cementitious Matrix) to reinforce historic masonry constructions. This strengthening technique has been applied in laboratory to reinforce masonry wall panels, tile brickwork vaults and to construct masonry ring-beams at eaves level of existing buildings. The mechanical behaviour of the reinforced masonry elements have been significantly enhanced and test results demonstrate that is possible to avoid the use of more traditional composite reinforcements like high-strength carbon fibres and epoxy resins to bond the reinforcing materials to the masonry substrate

    Shear resistance of screwed timber connections with parallel to grain FRP reinforcements

    Get PDF
    Several applications involving the use of Fibre Reinforced Polymers (FRP) glued on the tension side of timber beams are available in literature. However, some drawbacks (durability, product cost and health and safety restrictions, difficulties in removal) have limited an intensive use of organic adhesives (i.e. epoxy resins, etc). A possible solution could be the use of metal screws, changing the nature of the connection from chemical to mechanical. This paper describes an experimental investigation on the mechanical behaviour of externally bonded FRP composites using steel screws. Two different composite materials have been considered: Carbon Fibre Reinforced Polymer (CFRP) and Glass Fibre Reinforced Polymer (GFRP) and three different metal screw types have been used. FRP strengthening was then applied to timber blocks and shear tested conducted to study the performance of the screwed connection. The response of the screwed connection was recorded: catastrophic collapse did not occur, as the connection failed gradually for slippage phenomena produced by screw yielding and wood displacement. The slippage between timber and FRP plate has been recorded and tests described in this paper demonstrated that the effectiveness of screwed FRP strengthening could be compromised by these phenomena

    The Failure of Masonry Walls by Disaggregation and the Masonry Quality Index

    Get PDF
    The visual method for assessment of the structural behaviour of historic masonry walls, known by the acronym MQI (Masonry Quality Index) was introduced in 2002 by a team of researchers from the University of Perugia, Italy. This is based on a visual survey of the faces and the cross section of a wall panel, and it aims at verifying if a wall complies with the “rules of the art”. Based on this analysis, it is possible to calculate a numerical index: numerous tests, carried out on site by the authors to validate the method, have demonstrated that the index is able to provide useful information about the mechanical characteristics and structural response, in general, of the analysed wall panel. The failure mode of a wall panel under the action of an earthquake is a critical aspect. In general, the failure modes can be categorized in two classes: masonry disaggregation and the development of a local or global mechanism of wall elements (macroelements). Several theoretical models and numerical simulations only consider the latter. In this paper, application of the MQI method is further investigated, with particular emphasis to those masonry typologies which are more prone to collapse by disaggregation during a seismic event. Under the action of an earthquake, some types of masonry are typically unable to deform and to split in macroelements, and another type of failure occurs: this is the so-called “masonry disaggregation” or “masonry crumbling”. This type of failure anticipates the ones resulting from macroelement methods or stress analysis. As a conclusion, these latter methods become completely inappropriate and potentially hazardous, as they overestimate the seismic capacity of the building under investigation. The MQI method has been adapted to assess the structural response of different types of masonry under the action of an earthquake. In detail, the aim was to verify when the phenomenon of masonry disaggregation is likely to occur

    Jets, knots and tails in planetary nebulae: NGC 3918, K 1-2 and Wray 17-1

    Get PDF
    We analyze optical images and high-resolution, long-slit spectra of three planetary nebulae which possess collimated, low-ionization features. NGC 3918 is composed of an inner, spindle-shaped shell mildly inclined with respect to the plane of the sky. Departing from the polar regions of this shell, we find a two-sided jet expanding with velocities which increase linearly with distance from 50 to 100 km/s. The jet is probably coeval with the inner shell (with the age of approximately 1000 D yr, where D is the distance in kpc), suggesting that its formation should be ascribed to the same dynamical processes which also shaped the main nebula, and not to a more recent mass loss episode. We discuss the formation of the aspherical shell and jet in the light of current hydrodynamical and magnetohydrodynamical theories. K 1-2 is a planetary nebula with a close binary nucleus which shows a collimated string of knots embedded in a diffuse, elliptical shell. The knots expand with a velocity similar to that of the elliptical nebula (25 km/s), except for an extended tail located out of the main nebula, which linearly accelerates up to 45 km/s. We estimate an inclination on the line of the sight of 40 degres for the string of knots; once the orientation of the orbit is also determined, this information will allow us to test the prediction of current theories of the occurrence of polar jets from close binary systems. Wray 17-1 has a complex morphology, showing two pairs of low-ionization structures located in almost perpendicular directions from the central star, and embedded in a large, diffuse nebula. The two pairs show notable similarities and differences, and their origin is very puzzling.Comment: 20 pages plus 10 figures. ApJ recently published (ApJ 523, 721 (1999)
    • 

    corecore